MFT Calibrator / HART Communicator
|
 The MFT 4010 is a break-through combination calibrator / HART communicator
that truly reduces the time spent on field calibrations. The MFT 4010 Series delivers
the versatility of a calibrator and the convenience of HART communications in one
handheld unit. Users can view up to four measurements simultaneously on the
high resolution LCD or compare HART PV and AO values to corresponding values measured by the NIST traceable MFT. Available modules include differential, gauge, vacuum and absolute pressure as well as temperature and voltage/current. A voltage and current meter is integral to the base unit. All HART field devices can
be configured, polled and trimmed using HART communications. Device Specific
commands for supported devices are included with the MFT. MFT 4010 Advantages- All-In-One Tool – takes the place of multiple handheld instruments,simplifies workload and improves productivity.
- Automation for HART field devices – calibration is automated through auto setup of the calibrator based on the device settings; digital trims automatethe device adjustment steps.
- Calibration Types Supported – pressure, t/c, RTD, I/P, P/I, Switch, Loopand mA/V for conventional HART transmitter or local indicators.
- Document As found and As left Calibration Results – Create calibration procedures on the handheld or download them from compatible device management software. Save results to non-volatile memory.
- Field Updates – uses Internet downloads to update and add capability /HART support.
- Modules – select from a variety of positive-lock measurement modulesfor excellent versatility.
- Field Recertification – sensor modules and integral V/I can be recalibratedfor zero, span and linearity via the MFT.
- User Interface – 2.1” x 2.1” display, four soft keys (definitions change withmode requirements) and eight hard keys provide user interface. Display isconfigurable for 1 to 4 simultaneous measurements.
- User Convenience – Auto shut off, Damping, Min/Max value capture, displayHold, sensor Zero, direct Contrast adjustment.
- Security Lockout – Lockout specific MFT settings or all at one time. Diagnostics – MFT 4010 self-tests upon power up and upon installation ofsensor modules. Advisories are posted on the display.
- Dedicated DOF Memory – memory for 500 HART device drivers. Measurement Units – customary English and Metric System units are selectable.
|
|
|
|
Multifunctional Modular Calibrator
|
MFT 4000 -11-1-00 CE
|
|
Multifunctional Modular Calibrator with Intrinsic Safety
|
MFT 4000 -11-1-01 CE & IS
|
|
Multifunctional Modular Calibrator / HART® Communicator -
HART functions limited to analog and digital trims for supported pressure and temperature transmitters
|
MFT 4005 -11-1-00
|
|
Multifunctional Modular Calibrator / HART® Communicator - HART functions limited to analog and digital trims for calibration support with Intrinsic Safety
|
MFT 4005 -11-1-01
|
|
Multifunctional Modular Calibrator / HART® Communicator
|
MFT 4010
|
|
Multifunctional Modular Calibrator / HART® Communicator with Intrinsic Safety
|
MFT 4010-11-1-00 HART
|
|
|
PModules
|
|
For MFT 4000, 4005, 4010
|
RIO4000
|
|
For MFT 4000, 4005, 4010
|
TIO0110
|
|
|
|